Find Self Priming Pump, Sewage Pump, Dirt Drain Pump on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > Trailer Mounted Diesel Pump > SCP Non-Clog Lift Dewatering Pump

SCP Non-Clog Lift Dewatering Pump

Basic Info

Model No.:  SCP

Product Description

Model NO.: SCP Air Engine Type: Diesel Engine Transmission: Direct Connection Transmission Diesel Engine Pump System: Diesel Water Pump System Movable Diesel Water Pump: Movable Diesel Engine Pump Lift Pump: Trash Pump Specification: SGS HS Code: 841330900 Type: Self-Priming Pump With Inner Recirculation Theory: Gas-hydraulic Hybrid Type Structure: The Slide Movable Diesel Pump System: Diesel Pump System Groundwater Pump: Water Pump Trademark: Borra Origin: Wenzhou

The silenced diesel engine pump, developed with advanced technologies, is used for emergency fire control and living water supply.
Characteristics:
1. 1m noise measured 65dB(A)-85dB(A);
2. Silenced diesel engine pump, has a compact structure, small;
3. The vibration absorbed, to reduce vibration and noise;
4. Noise absorbed material-made cover, to reduce noise;
5. Noise absorbed compound silencer reduces noise;
6. High-efficient noise-off inlet channel;
7. Big-capacity fuel tank;
8. Cap plate, easy to maintain.



Conditions:
Altitude  ≤2500m
Ambient temperature -25~55ºC
Relative humidity 9~95%
Earthquake 7 degree
Flow range 50-700(L/S)
Head range 32-600m
Diesel engine power 18-1100KW
Media part materials  cast iron, graphite cast iron, stainless steel, cast copper.

Silenced diesel engine pump:
1. automatic start: when receive fire/piping network/power off/other start signals, in 5s, automatic start with full load;
2. automatic charging: the storage can carry out automatic charging by industrial power supply or diesel charging motor;
3. automatic warning: automatic warning for diesel engine low oil pressure, high water temperature, ultra speed;
4. automatic preheat: for emergency;
5. Direct coupling: under 360kw, diesel engine pump, innovative, flexible shaft couples, direct coupling.

·         Pump Operation
·         Do not operate a pump without having read and understood its Operations Manual. 
·         Do's
·         Always disconnect the negative battery cable before working on any pump.
·         Make sure all hose joints are properly connected before starting the pump.
·         Level the pump using jack stands or cribbing.
·         Install cribbing or support when using 8" or larger suction and discharge hoses.
·         Allow engine or motor to warm up before raising level to operating speed.
·         Raise and lower engine speed gradually.
·         Consult with us if operating an engine or motor over 1800 RPM.
·         Service diesel engines every 250 hours of running time.
·         Open drain valves on volute and non-return valves after shutting down a pump in freezing weather (ice can form and expand, possibly causing damage).
·         Take lines apart away from your body in case any remaining liquids spray.
·          
·         Don'ts
·         Don't touch the air compressor outlet line. It can be a hot surface!
·         Don't block air flow to the engine radiator (prevents overheating).
·         Don't pump liquids with a pH other than 7 (neutral). Internal corrosion may occur.
·         Don't pump heavy abrasive material. Internal corrosion may occur.
·         Don't run a diesel engine to the point of running out of fuel. The fuel delivery system will need to be bled prior to re-starting the engine.
·         Don't open the radiator cap while the engine is still warm.
·         Sustainability
·         We are committed to providing sustainable products and solutions with all of our pumps and products.  We offer tailored pump system design, with the right size and drive equipment for every job, to reduce unnecessary power and materials.
·        
Automated pump systems save energy and provide cleaner air and a healthier environment.  

Product Sustainability
·         Exhaust scrubbers for cleaner air
·         Biodegradable oil to help reduce potential damage to the environment
·         Critically silenced enclosures for reduced noise pollution
·         Office Sustainability
·         Recycling initiatives
·         Increased safety awareness
·         50% paper reduction by year-end


Technical parameters:

Type
Rotation speed
RPM
Flow Q Head H Power Diameter Particle diameter Maximum priming
m3/h 1/s m kW HP mm mm m
SCP-2 1150 15 4.2 4.0 1.1 1.5 50(2') 38 5.0
1450* 20 5.6 6.5 1.5 2 6.5
1750 25 6.9 9.5 3 4 6.5
2050 28 7.8 13.5 4.0 5.5 6.5
2350 32 8.9 18.0 7.5 10 6.5
2650 35 9.7 23.0 7.5 10 6.5
2900* 40 11.1 27.0 9.2 12.5 6.5
SCP-3 650 25 6.9 2 0.75 1 80(3') 63 1.5
750* 30 8.3 3 1.5 2 1.8
850 32.5 9.0 4 1.5 2 2.4
950* 40 11.1 4.5 1.5 2 3.0
1050 42.5 11.8 5.5 3 4 4.0
1150 45 12.5 7 4 5.5 4.9
1250 50 13.9 8 4 5.5 5.5
1350 52.5 14.6 10 5.5 7.5 5.8
1450* 55 15.3 11.5 5.5 7.5 6.4
1550 60 16.7 12.5 7.5 10 6.4
1650 65 18.1 14.5 11 15 6.7
1750 70 19.4 16 11 15 6.7
1850 72.5 20.1 18 15 20 7.6
1950 75 20.8 20 15 20 7.6
2050 80 22.2 22.5 18.5 25 7.6
2150 85 23.6 24.5 18.5 25 7.6
SCP-4 650 40 11.1 3 1.5 2 100(4') 76 1.5
750* 45 12.5 4 1.5 2 2.4
850 53 14.7 5 2.2 3 4.9
950* 60 16.7 6 3 4 5.8
1050 65 18.1 7.5 5.5 7.5 6.7
1150 72 20 9 5.5 7.5 7.3
1250 80 22.2 10.5 7.5 10 7.6
1350 85 23.6 12.5 11 15 7.6
1450* 100 27.8 13.5 11 15 7.6
1550 110 30.6 15.5 15 20 7.6
1650 115 31.9 18 18.5 25 7.6
1750 120 33.3 20 22 30 7.6
1850 130 36.1 22.5 30 40 7.6
1950 135 37.5 25 30 40 7.6
SCP-6 650 100 27.8 3.5 3 4 150(6') 76 2.4
750* 125 34.7 4.5 4 5.5 2.7
850 150 41.7 5.5 7.5 10 3.6
950* 160 44.4 7.5 7.5 10 4.2
1050 180 50 9 11 15 5.5
1150 200 55.6 10 15 20 6.4
1250 220 61.1 12.5 22 30 6.4
1350 230 63.9 15 30 40 6.7
1450* 250 69.4 17 30 40 7.0
1550 280 77.8 18 37 50 7.6
SCP-8 650 200 55.6 6 7.5 10 200(8') 76 2.7
750* 230 63.9 8 11 15 3.7
850 260 72.2 10 15 20 4.6
950* 300 83.3 12 22 30 5.2
1050 320 88.9 15 30 41 6.1
1150 350 97.2 18 37 50 6.4
1250 400 111.1 20 55 75 6.7
1350 450 125.0 23 75 102 7
1450* 500 138.9 26 75 102 7
SCP-10 650 250 69 6.5 11 15 250(10') 76 2.1
750* 300 83 8.5 15 20 3.4
850 350 97 11 22 30 4.3
950* 400 111 13 30 41 5.2
1050 450 125 16 45 61 5.5
1150 500 139 19 55 75 5.5
1250 525 146 23 75 102 5.8
1350 550 153 27 90 122 6.7
1450* 600 167 31 90 122 6.7

 