Find Boosting Pump, High Pressure Pump, Stainless Steel Pump on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > Centrifugal Pump > Other Centrifugal Pump > Vertical 1-Stage & Multi-Priming Fire Fight Pump

Vertical 1-Stage & Multi-Priming Fire Fight Pump

Basic Info

Model No.:  XBD-(I)

Product Description

Model NO.: XBD-(I) Type: Handheld Certification: ISO, SGS Electric Pump: Centrifugal Pump 1-Stage Pump: Fire Pump Vertical 1-Stage & 1-Priming Pump: Vertical Pump Fire Fight Pump: Fire Fight Diesel Pump Specification: ISO HS Code: 8413810090 Pressure Medium: Water Position of Pump Shaft: Vertical Edge Pump: Booster Pump Vertical 1-Stage Pump: Pump Pressure Pump: High Pressure Pump 1-Stage & 1-Priming Pump: 1-Priming Pump Trademark: Borra Origin: Wenzhou Vertical 1-Stage & Multi-Priming Fire Fight Pump

XBDL vertical 1stage & 1priming pumps system, used to transfer clear water and similar liquids with similar physical & chemical properties, without solid particles, applied and suitable in pressure boosted water supply in fire fight systems, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.
   XBD-L fire fight pumps system's performance and technical parameters comply with GB6245-1998 "Performance requirements and test methods for fire pumps", and obtains certificates from "China National Fire Fight Equipment Quality Supervision & Testing Center".
   Computer design and optimized processing, strong technical power, rich manufacture experiences and perfect test methods ensure stable and reliable quality.
Characteristics:
1. Compact structure, small, nice, vertical installation, less area for installation needed, gravity on feet, stable running and long life.
2. Stable running, little noise, highly concentric components.
3. Advanced hydraulic model, high efficiency and performance.
4. The superior mechanical shaft seal, highly endurable against friction, no leak, long life.
5. The pump inlet and outlet are on a same horizontal line, same sizes, easy to install and uninstall.
6. Easy to maintain, pipes uninstall is not needed, you only need take off pump cap nuts, then take out motor and transmission elements, before maintaining.

Technical parameters:
flow: 5-100L/S;
pressure: 0.10-1.25Mpa;
power: 1.1-250KW;
rotation speed: 980-2900r/min;
diameter: φ50-φ300;
temperature range:≤80ºC.
Model number Flow Q
(L/s)
Outlet pressure
(MPa)
Rotation speed n
(r/min)
Power P
(Kw)
Efficiency η
(%)
XBD3.0/5-50(65) 5 0.30 2900 4 63
XBD3.2/5-50(65) 0.32
XBD3.4/5-50(65) 0.34
XBD4.6/5-50(65) 5 0.46 2900 7.5 58
XBD4.8/5-50(65) 0.48
XBD5.0/5-50(65) 0.50
XBD7.6/5-50(65) 5 0.76 2900 15 50
XBD7.8/5-50(65) 0.78
XBD8.0/5-50(65) 0.80
XBD11/5-50(65) 5 1.10 2900 30 40
XBD12/5-50(65) 1.20
XBD12.5/5-50(65) 1.25
XBD3.0/10-65(80) 10 0.30 2900 7.5 71
XBD3.2/10-65(80) 0.32
XBD3.4/10-65(80) 0.34
XBD4.6/10-65(80) 10 0.46 2900 15 67
XBD4.8/10-65(80) 0.48
XBD5.0/10-65(80) 0.50
XBD7.6/10-65(80) 10 0.76 2900 22 59
XBD7.8/10-65(80) 0.78
XBD8.0/10-65(80) 0.80
XBD11/10-65(80) 10 1.10 2900 37 54
XBD12/10-65(80) 1.20
XBD12.5/10-65(80) 1.25
XBD3.0/25-80(100) 25 0.30 2900 15 76
XBD3.2/25-80(100) 0.32
XBD3.4/25-80(100) 0.34
XBD4.6/25-80(100) 25 0.46 2900 22 74
XBD4.8/25-80(100) 0.48
XBD5.0/25-80(100) 0.50
XBD7.6/25-80(100) 25 0.76 2900 37 69
XBD7.8/25-80(100) 0.78
XBD8.0/25-80(100) 0.80
XBD11/25-80(100) 25 1.10 2900 75 69
XBD12/25-80(100) 1.20
XBD12.5/25-80(100) 1.25
XBD13/25-80(100) 25 1.30 2900 90 57
XBD14/25-80(100) 1.40
XBD15/25-80(100) 1.50
XBD3.0/45-100(125) 45 0.30 2900 22 73
XBD3.2/45-100(125) 0.32
XBD3.4/45-100(125) 0.34
XBD4.6/45-100(125) 45 0.46 2900 37 77
XBD4.8/45-100(125) 0.48
XBD5.0/45-100(125) 0.50
XBD7.6/45-100(125) 45 0.76 2900 55 80
XBD7.8/45-100(125) 0.78
XBD8.0/45-100(125) 0.80
XBD11/45-100(125) 45 1.10 2900 90 70
XBD12/45-100(125) 1.20
XBD12.5/45-100(125) 1.25
XBD2.8/55-150(200) 55 0.28 1450 30 78
XBD3.0/55-150(200) 0.30
XBD3.2/55-150(200) 0.32
XBD4.6/55-150(200) 55 0.46 1450 45 75
XBD4.8/55-150(200) 0.48
XBD5.0/55-150(200) 0.50
XBD7.6/55-150 55 0.76 2900 75 76
XBD7.8/55-150 0.78
XBD8.0/55-150 0.80
XBD11/55-150 55 1.10 2900 110 73
XBD12/55-150 1.20
XBD12.5/55-150 1.25
XBD13/55-150 45 1.30 2900 110 80
XBD14/55-150 1.40
XBD15/55-150 1.50
XBD4.6/100-200 100 0.46 1450 75 81
XBD4.8/100-200 0.48
XBD5.0/100-200 0.50
XBD3.0/150-250 150 0.30 1450 75 80
XBD3.2/150-250 0.32
XBD3.4/150-250 0.34
XBD4.6/140-250 140 0.46 1450 90 72
XBD4.8/140-250 0.48
XBD5.0/140-250 0.50
XBD2.4/200-300 200 0.24 970 75 81
XBD2.6/200-300 0.26
XBD2.8/200-300 0.28
XBD2.8/200-300(350) 200 0.28 1450 90 84
XBD3.0/200-300(350) 0.30
XBD3.2/200-300(350) 0.32
XBD4.0/200-300 200 0.40 970 132 84
XBD4.2/200-300 0.42
XBD4.4/200-300 0.44
XBD4.6/160-300 160 0.46 1450 110 78
XBD4.8/160-300 0.48
XBD5.0/160-300 0.50
XBD4.6/200-350 200 0.46 1450 160 83
XBD4.8/200-350 0.48
XBD5.0/200-350 0.50
XBD2.8/300-400 300 0.28 1450 132 76
XBD3.0/300-400 0.30
XBD3.2/300-400 0.32
XBD2.8/330-500 330 0.28 1450 160 78
XBD3.0/330-500 0.30
XBD3.2/330-500 0.32


Vertical 1-Stage & Multi-Priming Fire Fight Pump

Start, running and stop 
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled by water. The pipes shall be sealed, no air leaked. (no-water inside start is forbidden) 
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check pump impeller, seal ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump. 
5. When rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen stuff cap. Adjust later when started.
5. In case fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on outlet pipe, close vacuum gauge cock.
2. Stop motor, and close pressure cock.
3. In Winter, drain liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean and lubricate.

Troubleshooting 
Fault Cause Solution
Pump cannot suck water, pressure gauge & vacuum gauge vibrating  1. Insufficient water pouring 
2. Leak between pipe and meter 
3. Suction is too high 
1, check leak in bottom valve. 
2, Tighten the leaked part 
3, reduce suction 
Pump cannot suck, high vacuum shown in vacuum gauge 1, bottom valve closed or jammed 
2, Too great water suction resistance 
3, filter jammed 
1, check bottom valve
2, replace water suction pipe
3, clear off filter
Pressure gauge works, no water outcome 1. Great outlet water pipe resistance
2. Wrong rotation direction 
3. Outlet pipe valve closed
4. impeller jammed 
1. check or shorten water pipe 
2, check motor, adjust 
3, open valve and clear off impeller
Cannot reach designed flow 1. air sucked 
2. Water level drops, submerged depth is not enough 
3. impeller jammed 
4. rotor torn and worn 
1, check leak part and clear off 
2, prolong water inlet pipe, increase submerged depth
3, uninstall and clear off 
4, replace seal ring 
Great pump power consumption 1. Stuff tightened, overheated 
2. Great flow 
3. Collision between rotor and case 
4. Pump shaft bearing abrasion 
5. Pump shaft misplaced
1. loosen slightly
2. reduce globe valve opening
3. adjust 
4. replace bearing 
5. replace or adjust 
Great pump vibration  1. impeller partially jammed 
2. impeller damaged 
3. little flow 
4. non-concentric between pump shaft and motor.
5,bearing damaged 
6, gas etching
1. Uninstall and clear off 
2, replace 
3, increase opening 
4, adjust
5, replace  
6, change suction inlet position 
Application range
Mainly applied in fire fight system pipes pressure boosted water supply, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.

Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure Pump、Boostering Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Centrifugal Pump > Other Centrifugal Pump