Vertical 1-Stage & Multi-Priming Fire Fight Pump
Basic Info
Model No.: XBD-(I)
Product Description
Model NO.: XBD-(I) Type: Handheld Certification: ISO, SGS Electric Pump: Centrifugal Pump 1-Stage Pump: Fire Pump Vertical 1-Stage & 1-Priming Pump: Vertical Pump Fire Fight Pump: Fire Fight Diesel Pump Specification: ISO HS Code: 8413810090 Pressure Medium: Water Position of Pump Shaft: Vertical Edge Pump: Booster Pump Vertical 1-Stage Pump: Pump Pressure Pump: High Pressure Pump 1-Stage & 1-Priming Pump: 1-Priming Pump Trademark: Borra Origin: Wenzhou Vertical 1-Stage & Multi-Priming Fire Fight Pump
XBDL vertical 1stage & 1priming pumps system, used to transfer clear water and similar liquids with similar physical & chemical properties, without solid particles, applied and suitable in pressure boosted water supply in fire fight systems, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.
XBD-L fire fight pumps system's performance and technical parameters comply with GB6245-1998 "Performance requirements and test methods for fire pumps", and obtains certificates from "China National Fire Fight Equipment Quality Supervision & Testing Center".
Computer design and optimized processing, strong technical power, rich manufacture experiences and perfect test methods ensure stable and reliable quality.
Characteristics:
1. Compact structure, small, nice, vertical installation, less area for installation needed, gravity on feet, stable running and long life.
2. Stable running, little noise, highly concentric components.
3. Advanced hydraulic model, high efficiency and performance.
4. The superior mechanical shaft seal, highly endurable against friction, no leak, long life.
5. The pump inlet and outlet are on a same horizontal line, same sizes, easy to install and uninstall.
6. Easy to maintain, pipes uninstall is not needed, you only need take off pump cap nuts, then take out motor and transmission elements, before maintaining.
Technical parameters:
flow: 5-100L/S;
pressure: 0.10-1.25Mpa;
power: 1.1-250KW;
rotation speed: 980-2900r/min;
diameter: φ50-φ300;
temperature range:≤80ºC.
Start, running and stop
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled by water. The pipes shall be sealed, no air leaked. (no-water inside start is forbidden)
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check pump impeller, seal ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump.
5. When rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen stuff cap. Adjust later when started.
5. In case fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on outlet pipe, close vacuum gauge cock.
2. Stop motor, and close pressure cock.
3. In Winter, drain liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean and lubricate.
Troubleshooting
Application range
Mainly applied in fire fight system pipes pressure boosted water supply, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities. Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure Pump、Boostering Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
XBDL vertical 1stage & 1priming pumps system, used to transfer clear water and similar liquids with similar physical & chemical properties, without solid particles, applied and suitable in pressure boosted water supply in fire fight systems, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.
XBD-L fire fight pumps system's performance and technical parameters comply with GB6245-1998 "Performance requirements and test methods for fire pumps", and obtains certificates from "China National Fire Fight Equipment Quality Supervision & Testing Center".
Computer design and optimized processing, strong technical power, rich manufacture experiences and perfect test methods ensure stable and reliable quality.
Characteristics:
1. Compact structure, small, nice, vertical installation, less area for installation needed, gravity on feet, stable running and long life.
2. Stable running, little noise, highly concentric components.
3. Advanced hydraulic model, high efficiency and performance.
4. The superior mechanical shaft seal, highly endurable against friction, no leak, long life.
5. The pump inlet and outlet are on a same horizontal line, same sizes, easy to install and uninstall.
6. Easy to maintain, pipes uninstall is not needed, you only need take off pump cap nuts, then take out motor and transmission elements, before maintaining.
Technical parameters:
flow: 5-100L/S;
pressure: 0.10-1.25Mpa;
power: 1.1-250KW;
rotation speed: 980-2900r/min;
diameter: φ50-φ300;
temperature range:≤80ºC.
Model number | Flow Q (L/s) | Outlet pressure (MPa) | Rotation speed n (r/min) | Power P (Kw) | Efficiency η (%) |
XBD3.0/5-50(65) | 5 | 0.30 | 2900 | 4 | 63 |
XBD3.2/5-50(65) | 0.32 | ||||
XBD3.4/5-50(65) | 0.34 | ||||
XBD4.6/5-50(65) | 5 | 0.46 | 2900 | 7.5 | 58 |
XBD4.8/5-50(65) | 0.48 | ||||
XBD5.0/5-50(65) | 0.50 | ||||
XBD7.6/5-50(65) | 5 | 0.76 | 2900 | 15 | 50 |
XBD7.8/5-50(65) | 0.78 | ||||
XBD8.0/5-50(65) | 0.80 | ||||
XBD11/5-50(65) | 5 | 1.10 | 2900 | 30 | 40 |
XBD12/5-50(65) | 1.20 | ||||
XBD12.5/5-50(65) | 1.25 | ||||
XBD3.0/10-65(80) | 10 | 0.30 | 2900 | 7.5 | 71 |
XBD3.2/10-65(80) | 0.32 | ||||
XBD3.4/10-65(80) | 0.34 | ||||
XBD4.6/10-65(80) | 10 | 0.46 | 2900 | 15 | 67 |
XBD4.8/10-65(80) | 0.48 | ||||
XBD5.0/10-65(80) | 0.50 | ||||
XBD7.6/10-65(80) | 10 | 0.76 | 2900 | 22 | 59 |
XBD7.8/10-65(80) | 0.78 | ||||
XBD8.0/10-65(80) | 0.80 | ||||
XBD11/10-65(80) | 10 | 1.10 | 2900 | 37 | 54 |
XBD12/10-65(80) | 1.20 | ||||
XBD12.5/10-65(80) | 1.25 | ||||
XBD3.0/25-80(100) | 25 | 0.30 | 2900 | 15 | 76 |
XBD3.2/25-80(100) | 0.32 | ||||
XBD3.4/25-80(100) | 0.34 | ||||
XBD4.6/25-80(100) | 25 | 0.46 | 2900 | 22 | 74 |
XBD4.8/25-80(100) | 0.48 | ||||
XBD5.0/25-80(100) | 0.50 | ||||
XBD7.6/25-80(100) | 25 | 0.76 | 2900 | 37 | 69 |
XBD7.8/25-80(100) | 0.78 | ||||
XBD8.0/25-80(100) | 0.80 | ||||
XBD11/25-80(100) | 25 | 1.10 | 2900 | 75 | 69 |
XBD12/25-80(100) | 1.20 | ||||
XBD12.5/25-80(100) | 1.25 | ||||
XBD13/25-80(100) | 25 | 1.30 | 2900 | 90 | 57 |
XBD14/25-80(100) | 1.40 | ||||
XBD15/25-80(100) | 1.50 | ||||
XBD3.0/45-100(125) | 45 | 0.30 | 2900 | 22 | 73 |
XBD3.2/45-100(125) | 0.32 | ||||
XBD3.4/45-100(125) | 0.34 | ||||
XBD4.6/45-100(125) | 45 | 0.46 | 2900 | 37 | 77 |
XBD4.8/45-100(125) | 0.48 | ||||
XBD5.0/45-100(125) | 0.50 | ||||
XBD7.6/45-100(125) | 45 | 0.76 | 2900 | 55 | 80 |
XBD7.8/45-100(125) | 0.78 | ||||
XBD8.0/45-100(125) | 0.80 | ||||
XBD11/45-100(125) | 45 | 1.10 | 2900 | 90 | 70 |
XBD12/45-100(125) | 1.20 | ||||
XBD12.5/45-100(125) | 1.25 | ||||
XBD2.8/55-150(200) | 55 | 0.28 | 1450 | 30 | 78 |
XBD3.0/55-150(200) | 0.30 | ||||
XBD3.2/55-150(200) | 0.32 | ||||
XBD4.6/55-150(200) | 55 | 0.46 | 1450 | 45 | 75 |
XBD4.8/55-150(200) | 0.48 | ||||
XBD5.0/55-150(200) | 0.50 | ||||
XBD7.6/55-150 | 55 | 0.76 | 2900 | 75 | 76 |
XBD7.8/55-150 | 0.78 | ||||
XBD8.0/55-150 | 0.80 | ||||
XBD11/55-150 | 55 | 1.10 | 2900 | 110 | 73 |
XBD12/55-150 | 1.20 | ||||
XBD12.5/55-150 | 1.25 | ||||
XBD13/55-150 | 45 | 1.30 | 2900 | 110 | 80 |
XBD14/55-150 | 1.40 | ||||
XBD15/55-150 | 1.50 | ||||
XBD4.6/100-200 | 100 | 0.46 | 1450 | 75 | 81 |
XBD4.8/100-200 | 0.48 | ||||
XBD5.0/100-200 | 0.50 | ||||
XBD3.0/150-250 | 150 | 0.30 | 1450 | 75 | 80 |
XBD3.2/150-250 | 0.32 | ||||
XBD3.4/150-250 | 0.34 | ||||
XBD4.6/140-250 | 140 | 0.46 | 1450 | 90 | 72 |
XBD4.8/140-250 | 0.48 | ||||
XBD5.0/140-250 | 0.50 | ||||
XBD2.4/200-300 | 200 | 0.24 | 970 | 75 | 81 |
XBD2.6/200-300 | 0.26 | ||||
XBD2.8/200-300 | 0.28 | ||||
XBD2.8/200-300(350) | 200 | 0.28 | 1450 | 90 | 84 |
XBD3.0/200-300(350) | 0.30 | ||||
XBD3.2/200-300(350) | 0.32 | ||||
XBD4.0/200-300 | 200 | 0.40 | 970 | 132 | 84 |
XBD4.2/200-300 | 0.42 | ||||
XBD4.4/200-300 | 0.44 | ||||
XBD4.6/160-300 | 160 | 0.46 | 1450 | 110 | 78 |
XBD4.8/160-300 | 0.48 | ||||
XBD5.0/160-300 | 0.50 | ||||
XBD4.6/200-350 | 200 | 0.46 | 1450 | 160 | 83 |
XBD4.8/200-350 | 0.48 | ||||
XBD5.0/200-350 | 0.50 | ||||
XBD2.8/300-400 | 300 | 0.28 | 1450 | 132 | 76 |
XBD3.0/300-400 | 0.30 | ||||
XBD3.2/300-400 | 0.32 | ||||
XBD2.8/330-500 | 330 | 0.28 | 1450 | 160 | 78 |
XBD3.0/330-500 | 0.30 | ||||
XBD3.2/330-500 | 0.32 |
Start, running and stop
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled by water. The pipes shall be sealed, no air leaked. (no-water inside start is forbidden)
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check pump impeller, seal ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump.
5. When rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen stuff cap. Adjust later when started.
5. In case fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on outlet pipe, close vacuum gauge cock.
2. Stop motor, and close pressure cock.
3. In Winter, drain liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean and lubricate.
Troubleshooting
Fault | Cause | Solution |
Pump cannot suck water, pressure gauge & vacuum gauge vibrating | 1. Insufficient water pouring 2. Leak between pipe and meter 3. Suction is too high | 1, check leak in bottom valve. 2, Tighten the leaked part 3, reduce suction |
Pump cannot suck, high vacuum shown in vacuum gauge | 1, bottom valve closed or jammed 2, Too great water suction resistance 3, filter jammed | 1, check bottom valve 2, replace water suction pipe 3, clear off filter |
Pressure gauge works, no water outcome | 1. Great outlet water pipe resistance 2. Wrong rotation direction 3. Outlet pipe valve closed 4. impeller jammed | 1. check or shorten water pipe 2, check motor, adjust 3, open valve and clear off impeller |
Cannot reach designed flow | 1. air sucked 2. Water level drops, submerged depth is not enough 3. impeller jammed 4. rotor torn and worn | 1, check leak part and clear off 2, prolong water inlet pipe, increase submerged depth 3, uninstall and clear off 4, replace seal ring |
Great pump power consumption | 1. Stuff tightened, overheated 2. Great flow 3. Collision between rotor and case 4. Pump shaft bearing abrasion 5. Pump shaft misplaced | 1. loosen slightly 2. reduce globe valve opening 3. adjust 4. replace bearing 5. replace or adjust |
Great pump vibration | 1. impeller partially jammed 2. impeller damaged 3. little flow 4. non-concentric between pump shaft and motor. 5,bearing damaged 6, gas etching | 1. Uninstall and clear off 2, replace 3, increase opening 4, adjust 5, replace 6, change suction inlet position |
Mainly applied in fire fight system pipes pressure boosted water supply, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities. Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about High Pressure Pump、Boostering Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Centrifugal Pump > Other Centrifugal Pump
Premium Related Products
Other Products
Hot Products
Lw Series Vertical Centrifugal Sewage Water PumpVerical Mining Pipeline Centrifugal Water PumpNon Clogging Marine Sewage Water PumpDisel Engine Double Suction Split Casing Irrigation Water PumpWater Supply Equipment with No Negative PressureDiesel Fire Pump for Vehicle Five TruckSewage Pump Whth Qw Not Easy to Wear and Clogging PipesHorizontal Self-Priming Chemical Centrifugal PumpHigh Efficiency Heavy Flow Vertical Axial Flow Irrigation Water PumpStainless Steel Horizontal Multistage Centrifugal Water PumpNon Negative Pressure Variable Frequency Constant Pressure Water Supply EquipmentHigh Efficiency Double Suction Split Casing Centrifugal Water PumpHorizontal Cantilever stainless Steel Chemical Proces Centrifugal Water PumpHigh Efficiency Vertical Pipeline Booster Centrifugal Water PumpHigh Efficiency Non-Clogging Submersible Sewage Centrifugal Irrigation Water PumpCentrifugal Water Pump for Water and Chemical Liquid