Xbc Diesel Fire Water Pump Set
Basic Info
Model No.: XBC
Product Description
Model NO.: XBC Air Engine Type: Diesel Engine Transmission: Direct Connection Transmission Diesel Fire Pump : Emergency Diesel Pumps Fire Fighting Pump: Diesel Pump Specification: ISO HS Code: 8413810090 Type: Self-Priming Pump With Inner Recirculation Theory: Gas-hydraulic Hybrid Type Structure: The Slide Clean Water Pump: Diesel Fire Fight Pump Trademark: Borra Origin: Wenzhou As per head, flow and media, the flow range: 10-870L/s, pressure range: 0.15-6MPa, diesel engine rotation speed range: 1500-2900rpm.
Used for emergency water supply in high buildings, taper water, steel factories, wine plants, chemical factories, hotels. Automatic, full functions, good structure, easy to install and use.
as per conditions: 1-stage 1-priming Centrifugal Pump, high-pressure multi-stage pump, 2-priming pump.
Run conditions:
1. Altitude: ≤2500m
2. Ambient temperature: -25~55ºC
3. Ambient relative humidity: 9~95%
4. Anti-earthquake degree: degree 7
5. Flow range: 50-700(L/S)
6. Head range: 32-600m
7. Power: 18-1100KW
8. Wet part materials: cast iron, graphite cast iron, stainless steel, cast copper.
Function specifications:
Diesel engine fire pump, electric pumps and stabilized Pressure Pump can form an automatic voltage fire Water Supply System and can realize linkage with fire control center. When diesel engine fire pump group received orders, if utility without powertime, then automatically Control Cabinet of diesel power immediately to the starter of pump group issued open signal, the starter, enggine idle starting, then gradually adjust diesel engine accelerator and make the diesel engine speed until the rated speed. The control system will automatic monitoring of diesel engine, such as the workings of diesel oil, oil temperature, rotational speed and pump outlet pressure, etc. Through the automatic monitoring to determine whether the normal starting diesel, if starting failure criterion control system will be issued to start signal, if 13 times are starting, the automatic control system failure will be issued starting failure alarming. When diesel engine fire pump group received pipe pressure recovery or mains supplyicoil resume normal signal, pump group will rapidly slow down and in idle position monitor after a period of automatic stop. Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Pump、Centrifugal Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
Used for emergency water supply in high buildings, taper water, steel factories, wine plants, chemical factories, hotels. Automatic, full functions, good structure, easy to install and use.
as per conditions: 1-stage 1-priming Centrifugal Pump, high-pressure multi-stage pump, 2-priming pump.
Run conditions:
1. Altitude: ≤2500m
2. Ambient temperature: -25~55ºC
3. Ambient relative humidity: 9~95%
4. Anti-earthquake degree: degree 7
5. Flow range: 50-700(L/S)
6. Head range: 32-600m
7. Power: 18-1100KW
8. Wet part materials: cast iron, graphite cast iron, stainless steel, cast copper.
Function specifications:
Diesel engine fire pump, electric pumps and stabilized Pressure Pump can form an automatic voltage fire Water Supply System and can realize linkage with fire control center. When diesel engine fire pump group received orders, if utility without powertime, then automatically Control Cabinet of diesel power immediately to the starter of pump group issued open signal, the starter, enggine idle starting, then gradually adjust diesel engine accelerator and make the diesel engine speed until the rated speed. The control system will automatic monitoring of diesel engine, such as the workings of diesel oil, oil temperature, rotational speed and pump outlet pressure, etc. Through the automatic monitoring to determine whether the normal starting diesel, if starting failure criterion control system will be issued to start signal, if 13 times are starting, the automatic control system failure will be issued starting failure alarming. When diesel engine fire pump group received pipe pressure recovery or mains supplyicoil resume normal signal, pump group will rapidly slow down and in idle position monitor after a period of automatic stop. Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Pump、Centrifugal Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Diesel Fire Pump System
Premium Related Products
Other Products
Hot Products
Lw Series Vertical Centrifugal Sewage Water PumpVerical Mining Pipeline Centrifugal Water PumpNon Clogging Marine Sewage Water PumpDisel Engine Double Suction Split Casing Irrigation Water PumpWater Supply Equipment with No Negative PressureDiesel Fire Pump for Vehicle Five TruckSewage Pump Whth Qw Not Easy to Wear and Clogging PipesHorizontal Self-Priming Chemical Centrifugal PumpHigh Efficiency Heavy Flow Vertical Axial Flow Irrigation Water PumpStainless Steel Horizontal Multistage Centrifugal Water PumpNon Negative Pressure Variable Frequency Constant Pressure Water Supply EquipmentHigh Efficiency Double Suction Split Casing Centrifugal Water PumpHorizontal Cantilever stainless Steel Chemical Proces Centrifugal Water PumpHigh Efficiency Vertical Pipeline Booster Centrifugal Water PumpHigh Efficiency Non-Clogging Submersible Sewage Centrifugal Irrigation Water PumpCentrifugal Water Pump for Water and Chemical Liquid