Diesel Fire Fighting Water Pump Fire Pump
Basic Info
Model No.: XBC
Product Description
Model NO.: XBC Air Engine Type: Diesel Engine Transmission: Direct Connection Transmission Diesel Engine Fire Pump: Diesel Water Fire Pump Water Pump: Pump Trademark: Borra Origin: Wenzhou Type: Self-Priming Pump With Inner Recirculation Theory: Gas-hydraulic Hybrid Type Structure: The Slide Fire Pump: Diesel Fire Pump Fire Fighting Pump: Diesel Engine Water Pump Specification: SGS HS Code: 841330900 The diesel engine multi-stage pump is composed of a diesel engine and pumps in a few stages, horizontal, single-priming and multi-stage, split-stage Centrifugal Pump. With a high efficiency, stable in run, wide application range, low noise, long life, easy to install and maintain. The fresh water, chemical media, or other fluids are ok. You can change the wet part materials, seals and cooling unit in order to transfer hot water, oil, corrosive media or media with tiny particles.
Characteristics:
1. High efficiency, wide application range.
2. Stable Run, low noise.
3. Spindle, soft cushion seal or mechanical seal, reliable, safe, simple, easy to maintain.
4. Full seal structure, no contact with media, no corrosion, a long life.
Technical parameters:
Flow: 6.3-500m3/h;
Head: 13-650m;
Power: 2.2-400KW;
Rotation speed: 1450-2950r/min;
Diameter: φ50-φ350;
Temperature range: ≤105ºC;
Work pressure: ≤3.0Mpa.
Technical parameters:
· Pump Operation
· Do not operate a pump without having read and understood its Operations Manual.
· Do's
· Always disconnect the negative battery cable before working on any pump.
· Make sure all hose joints are properly connected before starting the pump.
· Level the pump using jack stands or cribbing.
· Install cribbing or support when using 8" or larger suction and discharge hoses.
· Allow engine or motor to warm up before raising level to operating speed.
· Raise and lower engine speed gradually.
· Consult with us if operating an engine or motor over 1800 RPM.
· Service diesel engines every 250 hours of running time.
· Open drain valves on volute and non-return valves after shutting down a pump in freezing weather (ice can form and expand, possibly causing damage).
· Take lines apart away from your body in case any remaining liquids spray.
·
· Don'ts
· Don't touch the air compressor outlet line. It can be a hot surface!
· Don't block air flow to the engine radiator (prevents overheating).
· Don't pump liquids with a pH other than 7 (neutral). Internal corrosion may occur.
· Don't pump heavy abrasive material. Internal corrosion may occur.
· Don't run a diesel engine to the point of running out of fuel. The fuel delivery system will need to be bled prior to re-starting the engine.
· Don't open the radiator cap while the engine is still warm.
· Sustainability
· We are committed to providing sustainable products and solutions with all of our pumps and products. We offer tailored pump system design, with the right size and drive equipment for every job, to reduce unnecessary power and materials.
·
Automated pump systems save energy and provide cleaner air and a healthier environment.
Product Sustainability
· Exhaust scrubbers for cleaner air
· Biodegradable oil to help reduce potential damage to the environment
· Critically silenced enclosures for reduced noise pollution
· Office Sustainability
· Recycling initiatives
· Increased safety awareness
· 50% paper reduction by year-end
Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Pump、Centrifugal Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
Characteristics:
1. High efficiency, wide application range.
2. Stable Run, low noise.
3. Spindle, soft cushion seal or mechanical seal, reliable, safe, simple, easy to maintain.
4. Full seal structure, no contact with media, no corrosion, a long life.
Technical parameters:
Flow: 6.3-500m3/h;
Head: 13-650m;
Power: 2.2-400KW;
Rotation speed: 1450-2950r/min;
Diameter: φ50-φ350;
Temperature range: ≤105ºC;
Work pressure: ≤3.0Mpa.
Technical parameters:
Diesel engine pump | Rate flow m3/h | Rate head m | Rated rotation speed r/min | Pump type |
XBC8.0/13.9 | 30-50-60 | 84-80-75 | 2900 | IS80-50-250 |
XBC7.0/13.0 | 47 | 70 | 2900 | IS80-50-250A |
XBC6.0/12.2 | 44 | 60 | 2900 | IS80-50-250B |
XBC8.5/11.7 | 42 | 85 | 2900 | IS80-50-315B |
XBC11.0/13. | 47 | 110 | 2900 | IS80-50-315A |
XBC12.5/13.9 | 30-50-60 | 128-125-123 | 2900 | IS80-50-315 |
XBC5.0/27.8 | 60-100-120 | 54-50-47 | 2900 | IS100-65-200 |
XBC6.0/23.9 | 86 | 60 | 2900 | IS100-65-250B |
XBC7.0/25.8 | 93 | 70 | 2900 | IS100-65-250A |
XBC8.0/27.8 | 60-100-120 | 87-80-75 | 2900 | IS100-65-250 |
XBC10.0/25.0 | 90 | 100 | 2900 | IS100-65-315B |
XBC5.0/55.6 | 120-200-240 | 58-50-45 | 2900 | IS125-100-200 |
XBC6.0/48.1 | 173 | 60 | 2900 | IS125-100-250B |
XBC12.5/27.8 | 60-100-120 | 133-125-118 | 2900 | IS100-65-315 |
XBC8.0/55.6 | 120-200-20 | 87-80-72 | 2900 | IS125-100-250 |
XBC12.5/55.6 | 120-200-240 | 133-125-120 | 2900 | IS125-100-315 |
XBC11.0/52.8 | 190 | 110 | 2900 | IS125-100-315A |
XBC9.2/48.1 | 173 | 92 | 2900 | IS125-100-315B |
XBC5.0/111 | 240-400-460 | 55-50-45 | 1450 | IS200-150-400 |
XBC5.0/28 | 100 | 50 | 1450 | IS125-100-400 |
XBC5.0/28 | 200 | 50 | 1450 | IS150-125-400 |
XBC4.6/10 | 30-36-42 | 50-46-40 | 1450 | 75TSWA×4 |
XBC5.7/10 | 30-36-42 | 62-57-50 | 1450 | 75TSWA×5 |
XBC6.9/10 | 30-36-42 | 75-69-60 | 1450 | 75TSWA×6 |
XBC8.0/10 | 30-36-42 | 87-80-70 | 1450 | 75TSWA×7 |
XBC9.2/10 | 30-36-42 | 100-92-80 | 1450 | 75TSWA×8 |
XBC10.3/10 | 30-36-42 | 112-103-90 | 1450 | 75TSWA×9 |
XBC6.2/19.2 | 62-69-80 | 64-62-56 | 1450 | 100TSWA×4 |
XBC7.8/19.2 | 62-69-80 | 81-78-70 | 1450 | 100TSWA×5 |
XBC9.3/19.2 | 62-69-80 | 97-93-84 | 1450 | 100TSWA×6 |
XBC10.9/19.2 | 62-69-80 | 113-109-98 | 1450 | 100TSWA×7 |
XBC6.4/25 | 72-90-108 | 69-64-60 | 1450 | 125TSWA×3 |
XBC8.6/25 | 72-90-108 | 92-86-80 | 1450 | 125TSWA×4 |
XBC10.8/25 | 72-90-108 | 115-108-100 | 1450 | 125TSWA×5 |
XBC6.0/43 | 119-155-191 | 65-60-55 | 1480 | 150TSWA×2 |
XBC9.0/43 | 119-155-191 | 97-90-82 | 1480 | 150TSWA×3 |
XBC12.0/43 | 119-155-191 | 129-120-109 | 1480 | 150TSWA×4 |
XBC8.6/77.8 | 190-280-346 | 95-86-77 | 1480 | 200D1-43×2 |
XBC12.9/77.8 | 190-280-346 | 142-129-115 | 1480 | 200D1-43×3 |
XBC12.0/125 | 400-450-500 | 123-120-114 | 1480 | D450-60III×2 |
XBC11.4/139 | 450-500-550 | 120-114-108 | 1480 | D500-57×2 |
XBC12.0/200 | 550-720-850 | 132-120-108 | 1480 | D720-62×2 |
XBC5.0/60 | 150-216-260 | 59-50-45 | 1480 | D216-25×2 |
XBC7.5/60 | 150-216-260 | 88-75-67 | 1480 | D216-25×3 |
XBC10.0/60 | 150-216-260 | 118-100-90 | 1480 | D216-25×4 |
XBC12.5/60 | 150-216-260 | 147-125-112 | 1480 | D216-25×5 |
XBC6.5/134 | 360-485-612 | 71-65-56 | 1450 | 250S65 |
XBC9.0/219 | 590-790-936 | 93-90-82 | 1450 | 300S90 |
XBC7.8/210 | 576-756-918 | 86-78-70 | 150 | 300S90A |
XBC6.7/200 | 540-720-900 | 72-67-57 | 1450 | 300S90B |
XBC5.8/219 | 576-790-972 | 65-58-50 | 1450 | 300S58 |
XBC5.0/204 | 529-735-893 | 55-50-42 | 1450 | 300S58A |
XBC12.5/351 | 850-1260-1660 | 140-125-100 | 1450 | 350S125 |
XBC11.2/328 | 787-1181-1538 | 120-112-86 | 1450 | 350S125A |
XBC9.6/305 | 697-1098-1363 | 106-96-77 | 1450 | 350S125B |
XBC7.5/351 | 972-1260-1440 | 80-75-65 | 1450 | 350S75 |
XBC6.5/325 | 900-1170-1332 | 70-65-56 | 1450 | 350S75A |
XBC5.5/300 | 813-1080-1202 | 59-55-46 | 1450 | 350S75B |
· Pump Operation
· Do not operate a pump without having read and understood its Operations Manual.
· Do's
· Always disconnect the negative battery cable before working on any pump.
· Make sure all hose joints are properly connected before starting the pump.
· Level the pump using jack stands or cribbing.
· Install cribbing or support when using 8" or larger suction and discharge hoses.
· Allow engine or motor to warm up before raising level to operating speed.
· Raise and lower engine speed gradually.
· Consult with us if operating an engine or motor over 1800 RPM.
· Service diesel engines every 250 hours of running time.
· Open drain valves on volute and non-return valves after shutting down a pump in freezing weather (ice can form and expand, possibly causing damage).
· Take lines apart away from your body in case any remaining liquids spray.
·
· Don'ts
· Don't touch the air compressor outlet line. It can be a hot surface!
· Don't block air flow to the engine radiator (prevents overheating).
· Don't pump liquids with a pH other than 7 (neutral). Internal corrosion may occur.
· Don't pump heavy abrasive material. Internal corrosion may occur.
· Don't run a diesel engine to the point of running out of fuel. The fuel delivery system will need to be bled prior to re-starting the engine.
· Don't open the radiator cap while the engine is still warm.
· Sustainability
· We are committed to providing sustainable products and solutions with all of our pumps and products. We offer tailored pump system design, with the right size and drive equipment for every job, to reduce unnecessary power and materials.
·
Automated pump systems save energy and provide cleaner air and a healthier environment.
Product Sustainability
· Exhaust scrubbers for cleaner air
· Biodegradable oil to help reduce potential damage to the environment
· Critically silenced enclosures for reduced noise pollution
· Office Sustainability
· Recycling initiatives
· Increased safety awareness
· 50% paper reduction by year-end
Contact us if you need more details on Pump. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Pump、Centrifugal Pump. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Diesel Fire Pump System
Premium Related Products
Other Products
Hot Products
Lw Series Vertical Centrifugal Sewage Water PumpVerical Mining Pipeline Centrifugal Water PumpNon Clogging Marine Sewage Water PumpDisel Engine Double Suction Split Casing Irrigation Water PumpWater Supply Equipment with No Negative PressureDiesel Fire Pump for Vehicle Five TruckSewage Pump Whth Qw Not Easy to Wear and Clogging PipesHorizontal Self-Priming Chemical Centrifugal PumpHigh Efficiency Heavy Flow Vertical Axial Flow Irrigation Water PumpStainless Steel Horizontal Multistage Centrifugal Water PumpNon Negative Pressure Variable Frequency Constant Pressure Water Supply EquipmentHigh Efficiency Double Suction Split Casing Centrifugal Water PumpHorizontal Cantilever stainless Steel Chemical Proces Centrifugal Water PumpHigh Efficiency Vertical Pipeline Booster Centrifugal Water PumpHigh Efficiency Non-Clogging Submersible Sewage Centrifugal Irrigation Water PumpCentrifugal Water Pump for Water and Chemical Liquid